Check the breaker inside the house, make sure its not tripped. Holes in grids, or stitching coming apart Breakers do wear out, especially if used often as the pump switch. The pump was about 13 years old. },
I have a Hayward pump making more of a rattling sound inconsistent in nature. Fixing this issue can be tricky, so we suggest you get the help of a certified professional. Or is it coincidence that I have a bad line in the pool. Why does this keep happening? You can pull out the plunger and inspect, and see how it fits the valve body, at the top, should contact all sides, and be lubed well, twice per year. Pull out on the dial, and reset it, until you feel the gears engage. Blower vacuum switch open during post-purge error. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. What do you think is the problem? Then, take a look at the capacitor, located at 9 oclock. Thanks. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. Enzyme treatment to the pool can remove oils (if the sand seems oily), and Stain & Scale chemicals can tie up minerals like calcium (if the sand seems crusty). Hi Jacob, I would check the connections of the wires first. That could explain the pumping problems. But, you probably just need a $15 shaft seal, which is not overly difficult to replace. The pump should really be on its own breaker if possible. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. I have a dual flow 2 speed pump. Check the pump lid o-ring or gasket, and be sure the lid is very tight. There should be NO elbow after the flow switch. It was only 3 years old. Motor again started humming and had to repeat the above steps each time I moved to backwash. At the end of last year, I had a leak in the diverter valve. i removed the filter fingers and cleaned numerous times. Thanks, Jim, Jim, they can be sticky sometimes. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! He did notice that there was de inside of the filter grids so prior to putting it back together we completely flushed each of the grids making sure to get all the de out from inside of them. any advise would be appreciated . Is the motor set to accept 220V, and matching what you measure at the motor terminals? Could also be a clog in the pipe. So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. Tried to backwash. You must log in or register to reply here. Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. Did you figure this out.
Blue essence salt chlorine generator owner's manual Sometimes I am able to get it going by switching the breaker on/off several times, but most times I can hear the motor trying to start for a couple of seconds before it trips the breaker again and again. If yes, the motor bearings are the problem. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. "url": "https://blog.intheswim.com/"
Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). Amp draw is 15 amps. Heres a link to the Hayward Heater Owners Manual, which may be helpful. Any thoughts? I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. The Super Pump comes with all these labels that say it is set up and wired for 230. "caption": "In The Swim Blog"
Reset is immediate after error is corrected. It actually burned up shortly after my arrival and troubleshooting it. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Just purchased a Hayward SP32002VSP. hayward salt cell plumbing diagram blue essence 20 manual hayward aquarite troubleshooting guidehayward salt system troubleshooting aqua rite diagnostic codes Blue essence salt chlorine generator owner's manual Salt Chlorinator Cell Replacement, Salt Water System Parts, Pool Light, Pool Alarm, Pool. Is there a solution for this problem? Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Outlet works fine. All the readings (salt level, amps, etc) are in the correct range. I put new sand it its still dumping could it have been sand still in the line what you think or is there anything else that could cause this I put 200 lbs of sand in which is the correct amount . Now I am looking to replace the old filter. They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. You can remove the pump basket and reach back with your fingers to see if any debris can be felt in the eye of the impeller (pump Off, of course, lol). It could be dead. Just hoping for some feed back and the name plate is missing from the Tristar Motor, to actually know the exact motor we have? Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. I was able to isolate all the other electrical circuits at the Aqua Logic power panel. The pump has been running for 2 days. I have a maxi-flo 2 and it just stopped working. Inspect the motor for any burns evident on the casing as many times, an overheating motor will be shorted across the windings, and will soon fail. My Hayward mother is a 1.5 hp. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). Hi Kacy, thats very odd, and likely just a coincidence that the pump works on backwash only. Before you purchase a new Hayward pool pump, its important to verify that the pump is the right size for your pool piping. We have cleaned it 3-5 times a day and changed the d.e as well. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. Juat replaced motor. The high temp limit that is the pump motor as a thermal overload switch (located at 12 oclock in rear of motor), that will shut the motor down and prevent restart until the overload senses lower temps and resets itself, at which point the pump should turn on again, by itself. Maybe the transformer is not functioning properly? 58 amps! All pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; The pump is 18 yrs. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers. (returns are the lines going back to the pool, returning) Some pools can operate successfully with fewer than the original pipes, I have worked on many pools with abandoned main drains or skimmers that stopped working. Water temperature is above 140 degrees F. Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. Reassemble pump in reverse order from above. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. Lots of things to check, but its either air entering the system, or an obstruction, both on the suction side of the pump, or before the impeller. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. Hi Jimmy, no it need not have a controller, or a timeclock, it could just have an on/off (light type) switch. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. Is it plug and play? Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Thanks. Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. Thanks, Wouldnt turn back on for a while even after manually flipping the switch. If the motor was submerged, it may not recover. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. This pump is not even a year old. If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. At a total loss here, any suggestions would be greatly appreciated. Excuse my ignorance, but what could be the problem? "
Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Then it wouldnt turn back on. Hi probably not related to the vacuuming, but sounds like a motor problem. After filter was fully re-assembled- pump would turn on. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. My heater is not turning on, I dont see an error message but the light next to the fire icon is not on but the light in the yellow triangle is on, any idea on what that means? I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. Better call an electrician for that though, 2 speed Hayward pool pump motor is very loud only when on high speed. The process, for changing a hayward pump seal is: 1. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. Lighting Equipment Hayward Sense and Dispense AQL-CHEM Troubleshooting Manual (36 pages) Lighting Equipment Hayward SwimPure Plus Operation And Installation Manual (20 pages) Lighting Equipment Hayward Sheer 500 Owner's Manual Water feature with led lighting (16 pages) Lighting Equipment Hayward OmniHub Installation Manual The shaft turned with zero resistance. Could the filter be plumbed backwards possibly? I would guess this is what is happening, and if so your service company is either uneducated or dishonest. Pumps normal pressure and pulls enough volume to keep bakery full. You can also pressurize the suction lines using a Drain King, connected to a garden hose and inserted at the skimmer, with a plug inside of the pump on the incoming pipe, or setting the multiport valve on closed. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. I have a Hayward Perflex DE filter brand new last year. Thinking of switching to PentAir, I hear they are better built. Make sure there is no water in the conduit from the timer to the pump, and breaker to timer. When turned on, it clicks in and off every few seconds. Just curious if this area needs to be full at all times or just a steady flow on intake. Hayward, Create a Pool Owner Hi There I have a Hayward Super Pump VS pump. Sometimes its the filter that is drawing in air, thru the air bleeder or clamp band or bulkhead, which causes the filter to drain out through the pump, and back to the pool. I immediately unplugged it and the plug was black and the extension Outlet was melted. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. Recently I started getting a loud vibration hum from my hayward pump. The 2 bolts connecting it to the platform just turn and turn and go nowhere. We just has this pool installed year, and brought the motor inside the house. For AquaRite, move the switch from auto to off and check all of the readings. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. If it is not a clog, it could be a collapsed skimmer line or drain line, if flex pipe was used underground on these lines. Or if pump was off for some time, it can leak water, where it leaks air, when on. Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. any ideas? Hi Carolyn, if water is filling the waste water line (backwash line) when the pump is running, that means that the filter valve (multiport or push-pull valve) is leaking. Chapter 1: The Evil Emperor's Son. It could also be a clogged impeller or clogged filter, or clogged skimmer line. "dateModified": "05/20/2022",
Replaced battery on top of pump cover and still nothing??? Air problems dont usually cause the same loud noise, just the low basket water. When it cools it automatically trys to start again and motor turns on after 3 seconds of humming. 908-355-7995. low speed works fine, pump is three years old. Step 2: Did you properly install your switch? However it is not generating enough chlorine and we are adding chlorine more than we should. If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. "primaryImageOfPage": {
Automatic reset is 60 minutes. Please consider. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). It was probably spouting water several feet in the air, which soaked the motor, and popped a breaker? Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous.
How To: Troubleshoot a Hayward AquaRite - YouTube Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. Hi, I have a filter timer and a cleaner timer that are side-by-side. You are using an out of date browser. When it shuts off, you could also test power, to be sure power is still reaching the motor, with a multimeter tester. Or buy a new motor. Mt Tercer nivel ( dos elevadores ) 3 recamaras, Depto: 4 recamaras Salita de visitas Salita de TV 2, Diseado por travel organiser personalised. What could I be missing that would cause this? We are a registered 501(c)3 non-profit that is funded by user donations. I have a hayward pump installed as a new this March, 1.5 hp motor with a 23 inch filter to support a 12,000 gallons pool, it was working properly the first 3 months occasionally motor shut off and it wasnt by the breaker, since a week motor keep running only by 20 ,ins and suit off, touching the motor it is hot, I review filter pressure it is 15 psi, it is the same since installation. Is there a thicker housing oring that could be installed to fix the leak? The original pump (assy A) smells burnt. Ob, and its just over 4 yrs old. We would like to show you a description here but the site wont allow us. Just push the red button back in. You could remove the filter grid completely from the tank (and clean well), start the pump without the grid assembly inside (removing most of the resistance) and see how the water flows. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. I took apart the impeller and didnt see anything that could cause a problem. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. When this has been corrected, shut the power down to the pump and rest it after 15 minutes. Davy,
Hayward Blue Essense-20 | Trouble Free Pool When you start the pump on low, on the panel it does say load 2 and load 3, "on". },
This usually means the motor needs to be replaced. It could also be a loose switch in the back of the motor. If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). He said its drawing 58 amps. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. Products, View The error code will be cleared when the condition is corrected. I remplace it and now the sistem works!! of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. Usually OK with a 12 lift, but more than that can be a struggle. Hayward Blue Essence Troubleshooting, Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Do you have any advice? When I try to turn the pump back on, it only hums. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. If you pipes are underground, it could also be happening, if flex pipe was used and you have been using chlorine tablets in the skimmer. Air can also enter the system from low water level or a stuck skimmer weir, bringing air in from the skimmer, or from loose and leaky suction side (skimmer/main drain) valves. An error was detected in the ignition control circuit board. Is the water level ok in the pool, and the skimmer weir is not stuck? How To Recalibrate The Average Salt Level. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. Do I need to prime it? Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. presto, all working good! I have a Hayward HeatPro model HP21104T. I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesnt trip the breaker switch. Maintenance. 1.5 horse power. Yours may have become weak, or damaged somehow. Even the power light is not on. Dear Davy, my pump was working two days ago then I switched it off. What does F5 mean? 3 things are key, 1. If you like the Perflex filter, go with the Perflex EC75A, which is rated for 80 GPM, EC65A is only rated for 67 gpm. Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. Also make sure that the impeller wear ring is correctly facing, and that the seal plate and mounting screw are aligned properly, and that the diffuser and diffuser o-ring are seating properly. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. Put things back together and still have error. The water does not flow when the pump is turned on. For plug-in pumps, be sure the TEST button is not tripped on GFCI outlets, and that the cord is not damaged. 1. Also in reviewing the setup, the salt water panel box does not even turn on on low. If you find out, I would check the owners manual for information related to your symptoms. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. It likely also got hot and the threads shrunk, now drawing in too much air for the pump to catch prime. Excessive voltage or amps can cause the problem.
Hayward Pool Heater Troubleshooting - In The Swim Pool Blog It can also be a bad outlet, and if older than 20 yrs, it could be the breaker too. Should there be some form of gasket here? While holding the shaft and trying to remove the impeller there was a part that broke off the shaft on the electrical end and I dont know what the part is and cant find it to order it. Copyright 2022 In The Swim. I checked the breaker and plug connection and they were fine. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. You will get much more visibility by. Thanks for the schema!! Maybe thats off. Automation, Learn About (I just bought the house and am new to pool upkeep.). If the cell is still producing chlorine, it should be fine. At first, the pump would only hum and not work. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Hmmm, should work? What is the problem. You have both filter pump and polaris pump on one timer? We have a variable speed pump for filter and a single stage pump for cleaner. This year, I noticed at times that the flow rate on low speed is less than it was last year. It could have also overheated, when this happens, it will work again after cooling down. Pump lids are all very tight, they need to be. I noticed the pump wasnt running this week and saw the LED display was off and had moisture in it. 9-17-2020 Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Found this blog, followed the instructions by removing the capacitor and thermal overload, turnied the shaft with a 7/16s. If dead, you can replace just the motor and shaft seal, re-using the pump and impeller. Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! I was only able to read and yes feel voltage in the pool when the main pump was running only. Lube should not be the issue with the leak, not required. Hi Mike, pumps are too hot to touch normally, running at 140 or so. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. Suggestions ? A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. The pump does not start. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Now wont turn on when I plug back in and my circuit breakers are not popped. could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. 1. The previous owners winterized the pump and pool but left all the water in the pool so its full and nasty. The outlet has been replaced and the issue is still happening. I added new wire and plug end but when I plug it in it trips the breaker. Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow.