Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Then after a bit, the pump restarts. Ordered new ones. Step 3 First, verify the power is turned off at the breaker panel. ft. home is a 3 bed, 4.0 bath property. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. Did you try to flip the switch of the timeclock? Only perform this step if you are qualified. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? . Pop-in a new timer mechanism, and replace the wires to the previous configuration. GFCI breakers trip at a very low threshold, doesnt take much. If all looks well, and the gears are still not turning, you may need to replace the mechanism. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Or be loose and not making good contact. I went to the control panel and saw that the timer needle stopped just after the start pointer. #1. "headline": "Intermatic Pool Timer Troubleshooting",
My time clock has an ant infestation! Today is the second day that I have had to turn it on manually. Followed all directions and even watched YouTube troubleshooting videos. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Also, does it sound like the power is not leaving the breaker? Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Check the motor, and be sure the label is not printed 50 hz. Start with the easy checks. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. I used to run the pump for 8-9 hrs a day. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. The gears in mechanical timers can get damaged. When I put the new one on, the trippers do not work. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. If the pump comes on, you definitely have power to the timer. I believe its the manual on/off switch that is the problem. Make sure the middle time pointer is tight. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. the trippers are even slightly damaged the timer won't work correctly. As you release the dial, you will feel the gears engage. Morgan Burley My timer doesnt seem to be working or my pump in either speed. I think I have found it. Related Reading: Should You Get a Pool Pump Timer? What Im wanting to do is just disable the turn off/on and just keep power 24/7. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). A power surge may have taken out the timer or the pump. Terminal A (farthest to the left side) is not connected to anything. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hello, newer pool guy here. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Thanks! I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Proceed to step 4 to check the timer itself. When the trippers are done up, you shouldnt be able to move them with your hands. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! For additional tripper pairs on CLOCK-DIALorder 156T1978A. Im wanting to use T101 to wire my above ground pool pump. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . The capacitor for the motor may be bad. Hi Davy, (For outside light timer) The one before was original to the house & I had no trouble. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Everythings OK now, unit works just fine. Not sure if you still answer these but I have a weird one for you. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Sometimes its way quick just to replace it rather than spend hours troubleshooting. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. I had a thunderstorm last night and my power went off for like 3 hours. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. The power should run from the breaker, to the timer, to the pump. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. I have an Intermatic t104. The mechanism for the off tripper doesn't work at all when manually depressed. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. "identifier": ""
Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Still no luck. Reset the clock to the correct time. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. To do this, pull the yellow-faced time dial (clockface) toward you. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. I am having the same problem. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? It stays on until I turn off the circuit breaker. The rest of your setup is probably fine. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Grab it, pull it towards you, move it around then place it back down. If its not, it wont work properly. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. See the next section in this article for that. Gently tighten the screws to securely hold the dogs in place. What was the fix?? Theres really only 3 causes as to why your pump wont turn on/off. Now try to jiggle it on and off. Did I wire it incorrectly or did I just get a bad timer? Thanks. Dont know what the issue is. Hi Carlos, is there a GFCI outlet in the circuit? This div height required for enabling the sticky sidebar. DEWENWILS Outdoor Outlet Box. It should loosen up after a few goes when the grease and gunt dissolve. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. I have a PF1112T. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). The problem lies, where the power dies, as they say, Thanks for the response. Reasons Why Pool Timers Stop Working 1. They should be straight, if not, replace them. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. Manual switch works my aerator. Hi Mike, yes I sent you an email to your yahoo acct. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. i have an oval pool that is closed for the winter but there ha been a problem. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
You can find this in your power board. The timer appears to be working fine (keeps time). I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Any ideas why its doing that? Now, Im going to order some additional timer clips. If I manually push the lever, it moves without much pressure. Turn the metal bar until it contacts one of two plastic side tabs. For Sale: 2 beds, 2 baths 1152 sq. It randomly loses the time that it is set to. Your timer is on a 24-hour cycle. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. Hi, Davy, seeing lots of complaints here. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. My clock seems to work but but the on and off switch does not turn on the pool pump. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Any advice on how to fix. The pool timers I have had down there . View more property details, sales history and Zestimate data on Zillow. Take them off and inspect them. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. Or there could be a bad relay in the control panel, if you have ice cube style relays. Ill do the same. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Clock wont move, gear dont move at all. Pool co says T104 timer needs replacement and filter cartridge. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. not sure what is the problem. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. If the pump doesnt come on, follow the steps below. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. Any suggestions? On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Hello. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. The trippers can also get damaged. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. It is not warped in any way. Does this mean I need a new T104, or is there a replacement manual on/off switch? After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Reset the clock on the timer to the correct time to get it back to the desired on/off times. Watch these tips and tricks before replacing it. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. My intermatic pool timer will not automatically turn on. AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. It may or may not reduce the noise level however. One morning I noticed my pool didnt automatically turn off. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. I dont see timer gears rotating on any power going to the pump or salt system. Hello. Move the start and stop pins to appropriate times for swimming pool filter operation. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Theres an issue with the wiring between the circuit breaker and the timer. Please advise. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Now The ice and snow have melted and the cover is getting in deeper. Pool pump timers can last up to 20 years, depending on the model. I hope this helps. Turn the power off at the breaker box and carefully remove the wires to the clock. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. "@type": "ImageObject",
It is still moving and it will trip off but not on. Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. If it doesnt, there could be an issue with the clock face or gears. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! It should be 110V or 220V AC. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Can I wire this timer to an outlet or should I search for another solution? "logo": {
The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Hi there, Is there anything else I can do or do I need to get a new one? I can manually turn it on with the lever at the bottom. Hey there! 1. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. It just stays at that time. Hello Davy, Terry here again. the problem lies, where the power dies as they say. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. During this the pump cannot be manually switched on. I have a white, red, and black wire coming from the power source. Why it always stop around 10pm by itself and not moving again? P.S. Do you have an answer to why my pump wont turn off or on? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. You should always be able to switch your pump on and off manually at the timer. Im ready to send my back for a replacement. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. We cover T101, T103 and T104 models of mechanical pool timers. You will first want to look at the pool timer and see if you have two timer pins. Flip off the breaker. We may earn a small commission. Flip it from where it is now, to the opposite side. There should be an off pin and an on pin. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. There's an issue with the wiring between the circuit breaker and the timer. Hi Rich, is one of those wires (white?) Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Inside, the 1 gear on the right side can be removed to access a metal bar. "width": "611",
My timer clock does not run and the manual on off switch does not turn off the pump motor. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool.